SCADA system
We create custom SCADA systems that give operators real-time equipment views, prioritized alarms, and historical trends, while enabling authorized supervisory commands at plants and remote sites.
Based on more than 100 recent reviews
control] D --> G[Operational
reports] class C,E,F accent; classDef accent fill:#8b71fb,stroke:transparent,color:#fff;
How a SCADA system works
A SCADA monitoring system collects equipment data and presents it on operator screens, as alarms, and through historical trends. SCADA stands for supervisory control and data acquisition: it coordinates supervision rather than replacing local controllers. SCADA monitoring system collects equipment data and presents it on operator screens, as alarms, and through historical trends. SCADA stands for supervisory control and data acquisition: it coordinates supervision rather than replacing local controllers.
In a SCADA PLC system, PLCs retain time-critical control and safety functions; supervisory commands remain subject to controller interlocks. Your solution may include the interfaces below, tailored to your equipment, sites, and procedures.
- Equipment connections - Collect timestamped telemetry from PLCs, RTUs, and gateways through compatible interfaces such as OPC UA and MQTT.
- Operator workspace - Display process diagrams, alarm priorities, acknowledgements, and permission-controlled commands in one HMI.
- Historical data workspace - Compare trends and investigate events using timestamps and data-quality indicators.
- Site dashboards - Display equipment availability, stale readings, connection failures, and operational reports.
- Business system connections - Exchange agreed records with CMMS and ERP systems and connect an identity provider for user access.
To define the development scope, map controllers, tag volumes, screens, alarm rules, retention needs, and deployment constraints. These determine the amount of integration and commissioning work.
Why your operations need a SCADA system:
Why disconnected work slows response
Separate displays and manual readings slow fault detection and leave operators without a reliable shared overview. Calls to local staff can delay equipment changes, while missing records make incidents harder to explain.
SCADA system security requires more than a login screen. Bounded permissions, segmented networks, controlled remote access, and logged actions reduce unnecessary exposure; controller interlocks and local safety functions must remain in place.
- Fragmented status - Operators spend time reconciling separate displays instead of assessing the current situation.
- Unprioritized faults - Repeated notifications conceal urgent alarms and acknowledgement history remains unclear.
- Missing history - Manual records leave gaps when engineers investigate process changes or equipment failures.
- Untracked changes - Informal remote instructions make it difficult to establish authorization and accountability.
- Silent connection failures - Old readings may appear fresh when communication failures and telemetry freshness are not visible.
Assess the current situation
Using a SCADA system starts with confirming which readings are fresh and which assets need attention.
-
Review sites
Check equipment states, connection health, and stale readings.
-
Check trends
Compare the current situation with previous operating periods.
Investigate and respond
Operators assess urgent faults in context before deciding on the appropriate action.
-
Handle alarms
Confirm priority events and follow the configured response procedure.
-
Investigate conditions
Use process screens and event history to investigate the affected equipment.
Act and hand over
Authorized operators make supervisory changes and leave a traceable record for handover.
-
Issue commands
Submit permitted changes while following controller interlocks, and verify the returned state.
-
Review reports
Review alarms, recorded actions, and unresolved issues for the next shift.
How AI can enhance your system
Optional AI helps operators investigate telemetry and events that are difficult to review manually. Its usefulness depends on the available data, equipment context, and approved source material.
- Anomaly detection - Rank unusual telemetry patterns against historical operating behavior for operator review.
- Alarm grouping - Suggest relationships between alarms based on event timing and equipment context to help investigate alarm floods.
- Maintenance insights - Highlight indicators of wear from telemetry and maintenance history for engineering assessment.
- Operations assistant - Explain equipment events using available records and approved guidance, with source references.
Operators assess every recommendation. AI does not issue control commands or replace deterministic alarms, controller interlocks, or safety functions. Historical data can be used to assess recommendations before allowing them into operational workflows.
How much does a custom SCADA system cost?
Every project is built to order. The options below show a typical scope and a larger custom solution; estimates are influenced by equipment, sites, interfaces, screens, alarms, historical data retention, security, deployment, and commissioning requirements.
Project estimate
A custom SCADA solution for a defined process area with real-time monitoring, alarm handling, and role-based access.
-
Modules
- Data acquisition
- Operator screens
- Alarm management
- User access
-
Support
- Commissioning and training
- 6 months of support + extended support option
-
Integrations
- PLCs and RTUs
- OPC UA servers
-
Extended warranty
-
About €150 - €750 / month - full coverage, including VPS hosting, priority support, all fatal, logic, core, form, and layout issues, and vendor/API replacement if external integrations become unstable or deprecated.
-
Enterprise or custom solution
An enterprise-wide SCADA solution for distributed operations with historical data investigation, traceable supervisory commands, and advisory AI that leaves control decisions to authorized personnel.
-
Modules
- Historical data
- Supervisory control
- Remote sites
- Audit trail
- Anomaly detection
- Alarm grouping
- Maintenance insights
- Operations assistant
-
Integrations
- PLCs and RTUs
- OPC UA servers
- CMMS
Shall we make a prototype?
With the most advanced AI solutions we build a clickable, interactive prototype of your system in one working day. With realistic test data, ready for presentations and further system design.
- Clickable main screens, made by AI
- A link to share with your team
- The scope of the first version
- A fixed price for the development
No obligation: you pay only for the prototype.
We build SCADA solutions for your operations:
From water treatment systems to energy and industry, we tailor monitoring and supervisory control to your equipment, sites, and operator workflows.
Water utilities
Treatment plants
Energy companies
Industrial plants
Clear terms from scope to handover:
You receive a price range before the technical specification, which takes about 5 business days to prepare. Compensation for exceeding agreed deadlines is specified in the contract. Free basic and post-launch support lasts 6 months after handover.
Milestone payments
Work begins
Milestone acceptance
Source code ownership
Questions before ordering a SCADA system:
Working with 2410
Technical decisions
Projects related to your SCADA solution:
Explore related systems and modules in the 2410 portfolio, with features supporting the monitoring, integration, and workflows described here.
Modbus TCP monitoring software for live sensor data
Industrial equipment
Latvia
The client needs to monitor the condition of connected equipment, process variables, and environmental readings.
The solution became a modular Modbus TCP monitoring workspace with real-time dashboards, data logging, alerts, and reports.
The software helps reduce manual monitoring work and keep equipment data available for review.
Get an AI-generated estimate for your SCADA software
Describe your sites, equipment, and interfaces, operator workflows, deployment constraints, and supervisory control requirements to receive an AI-generated project estimate.